{"product_id":"drive-medical-nexstride-visual-auditory-cueing-device-fg1000","title":"Drive Medical NexStride Visual \u0026 Auditory Cueing Device for Gait Support FG-1000","description":"\u003cp\u003eThe NexStride is a gait aid that attaches to a cane, walker, rollator or walking poles and provides two external cues to help a user start and sustain walking. A green laser line projects onto the floor ahead of the feet to give a visual target to step over, and an adjustable metronome provides an audible beat to step in time with. Either cue can be used on its own or both together.\u003c\/p\u003e\n\u003cp\u003eThe unit straps to the pole of the mobility aid, with a separate hand controller mounted near the handle so cues can be switched on and off without reaching down while walking. External cueing of this kind is often used by people with Parkinson's disease who experience freezing of gait. A physical therapist or movement disorder specialist can advise on how to set the cues up and use them effectively.\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGreen laser line that projects a visual stepping target onto the floor\u003c\/li\u003e\n\u003cli\u003eAdjustable metronome with cadence and volume controls\u003c\/li\u003e\n\u003cli\u003eLaser head rotates in multiple directions to position the line\u003c\/li\u003e\n\u003cli\u003eHand controller that switches each cue on and off independently\u003c\/li\u003e\n\u003cli\u003eRubber strap mounting that fits canes, walkers, rollators and walking poles\u003c\/li\u003e\n\u003cli\u003eRechargeable internal battery with a colour-coded charge indicator\u003c\/li\u003e\n\u003cli\u003eRetractable USB charging cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow It Works\u003c\/h4\u003e\n\u003cp\u003eThe laser line and metronome act as external cues, which are intended to give the brain a target and a rhythm to organize movement around. Positioning the line in front of the feet gives a visible mark to step over, and setting the metronome to a comfortable walking tempo gives a beat to step in time with. Both are designed to help a user initiate and continue walking, and may help with stride length and turning.\u003c\/p\u003e\n\u003ch4\u003eIndications\u003c\/h4\u003e\n\u003cp\u003eA gait aid that uses visual and auditory cues to increase mobility.\u003c\/p\u003e\n\u003ch4\u003eDirections for Use\u003c\/h4\u003e\n\u003cp\u003eTo attach the device:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eHold the back of the NexStride flat against the pole of the mobility aid. Hook one rubber strap to the device, wrap it around the pole, and hook it to the other side to secure the unit.\u003c\/li\u003e\n\u003cli\u003eAttach the controller the same way with the second strap, positioning it near the handle of the mobility aid.\u003c\/li\u003e\n\u003cli\u003eConnect the retractable cable to the NexStride and pull the cord up to the controller, pulling from both ends at once. Wipe the pole with the supplied alcohol wipe and let it dry, then peel the backing from the magnet and stick it to the pole where the cable sits best.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTo use the cues:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFor the laser line, position it either directly in front of your feet or a few feet ahead, then step over or toward the line.\u003c\/li\u003e\n\u003cli\u003eFor the metronome, rotate the cadence knob to set a comfortable walking tempo, then step to the beat.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eRead the user manual before first use. A physical therapist or movement disorder specialist can help set the cues up for your walking pattern.\u003c\/p\u003e\n\u003ch4\u003eSafety Information\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe NexStride is not guaranteed to prevent or mitigate freezing of gait or falling. Walk safely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e position the laser where anyone could look directly into the beam, and \u003cstrong\u003edo not\u003c\/strong\u003e view the beam through a telescope, magnifier or other optical device. Serious eye injury could result.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e operate the laser around children, or allow children to operate it. Store the device out of reach of children and anyone untrained in its use.\u003c\/li\u003e\n\u003cli\u003eTurn the laser off when it is not in use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e open, disassemble, repair or modify the device. There are no user-serviceable parts inside and modification may cause hazardous laser radiation exposure. Contact the manufacturer for repairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e remove or deface any warning label on the device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e use the device in the rain. It is not waterproof. Keep it away from moisture and do not insert anything into any opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e use the device if it is cracked, frayed, broken, otherwise damaged, or fails to operate. Discontinue use if damage is suspected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e drop or step on the device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e operate the device outside its operating temperature range.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFG-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDrive Medical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCue Types\u003c\/td\u003e\n\u003ctd\u003eGreen laser line and audible metronome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd\u003eOn\/off, metronome cadence, volume, laser angle, plus a separate hand controller for laser and metronome on\/off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eInternal rechargeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eApproximately 6 to 8 hours with the laser and metronome both running\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge Indicator\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eGreen:\u003c\/strong\u003e 50 to 100 percent. \u003cbr\u003e\u003cstrong\u003eYellow:\u003c\/strong\u003e 25 to 49 percent. \u003cbr\u003e\u003cstrong\u003eRed:\u003c\/strong\u003e 0 to 24 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging\u003c\/td\u003e\n\u003ctd\u003eRetractable USB cable with wall adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e6 oz (170 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRubber straps, 2 supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Resistance\u003c\/td\u003e\n\u003ctd\u003eNot waterproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e32 to 113 degrees F (0 to 45 degrees C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 113 degrees F (-20 to 45 degrees C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1 year against defects in material and workmanship under normal use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eResources\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2808\/7360\/files\/User_Manual_-_Drive_Laser_and_cueing_device.pdf?v=1787681023\" rel=\"noopener\" target=\"_blank\"\u003eNexStride User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePackage Includes\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 NexStride unit with rechargeable battery\u003c\/li\u003e\n\u003cli\u003e1 NexStride hand controller\u003c\/li\u003e\n\u003cli\u003e1 retractable USB cable\u003c\/li\u003e\n\u003cli\u003e1 charging adapter\u003c\/li\u003e\n\u003cli\u003e1 adhesive-backed magnet\u003c\/li\u003e\n\u003cli\u003e2 rubber straps\u003c\/li\u003e\n\u003cli\u003e1 alcohol wipe\u003c\/li\u003e\n\u003cli\u003e1 user guide\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Drive Medical","offers":[{"title":"Default Title","offer_id":44321727086705,"sku":"DMCFG-1000","price":1323.63,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2808\/7360\/files\/FG-1000_1.jpg?v=1787681076","url":"https:\/\/healthcaresolutions.ca\/products\/drive-medical-nexstride-visual-auditory-cueing-device-fg1000","provider":"Healthcare Solutions","version":"1.0","type":"link"}