{"product_id":"drive-solite-pro-low-homecare-bed-frame-only","title":"Drive Medical Solite Pro Low Homecare Bed Frame Only","description":"\u003cp\u003e\u003cstrong\u003eBed frame only. Mattress, side rails and grab handles are sold separately. \u003cbr\u003eSafe working load: 421 lb (191 kg), including occupant, mattress and accessories. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Drive DeVilbiss Solite Pro Low is a fully electric homecare bed frame with covered bed ends, designed for use at home or in long-term care, rehabilitation and geriatric care settings. This low hospital-style bed raises the mattress platform so a caregiver can work at a comfortable standing height, and lowers it close to the floor, where Drive recommends leaving it when the occupant is unattended to help reduce the risk of injury from a fall. The backrest and leg section adjust independently or together with auto-contour, and an electric foot-down tilt helps with repositioning.\u003c\/p\u003e\n\u003cp\u003eThe profiling bed frame separates into four sections without tools and comes with built-in transport stands for moving and storage, making it practical for home delivery and setup. A single handset controls all functions and includes a key-operated lockout, so a caregiver can disable any movement that is unsuitable for the occupant.\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFully electric height adjustment, backrest, leg section and foot-down tilt\u003c\/li\u003e\n\u003cli\u003eLow bed design that brings the occupant closer to the floor\u003c\/li\u003e\n\u003cli\u003eAuto-contour adjusts the backrest and leg section together\u003c\/li\u003e\n\u003cli\u003eAuto-regressing backrest\u003c\/li\u003e\n\u003cli\u003eLeg section with angle and height adjustment modes\u003c\/li\u003e\n\u003cli\u003eIntegral mattress platform and leg section extension for taller users\u003c\/li\u003e\n\u003cli\u003ePatient handset with individual function lockout and key\u003c\/li\u003e\n\u003cli\u003eStandard handset omits head-down tilt (Trendelenburg) for safety; a replacement handset with this function is available if clinically required\u003c\/li\u003e\n\u003cli\u003eSeparates into sections with built-in transport stands - no tools required for assembly\u003c\/li\u003e\n\u003cli\u003eIndividually braked castors for moving the bed within a room\u003c\/li\u003e\n\u003cli\u003ePowder-coated steel frame with covered bed ends\u003c\/li\u003e\n\u003cli\u003eSplash-resistant electrical system\u003c\/li\u003e\n\u003cli\u003eCompatible with Drive accessories including side rails and grab handles, sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Drive DeVilbiss Healthcare\u003c\/li\u003e\n\u003cli\u003eItem number: 15006LP\u003c\/li\u003e\n\u003cli\u003eProduct code: SOLITE\/PRO\/LOW\/CA\u003c\/li\u003e\n\u003cli\u003eSafe working load: 421 lb (191 kg) - occupant, mattress and accessories combined\u003c\/li\u003e\n\u003cli\u003eMaximum patient weight: 421 lb (191 kg)\u003c\/li\u003e\n\u003cli\u003eMinimum patient weight: 88.2 lb (40 kg)\u003c\/li\u003e\n\u003cli\u003ePatient height: 57.5 to 79.1 in (146 to 201 cm), upper limit with bed extended\u003c\/li\u003e\n\u003cli\u003eBackrest angle (max): 72 degrees\u003c\/li\u003e\n\u003cli\u003eLeg section angle (max): 21 degrees\u003c\/li\u003e\n\u003cli\u003eKnee break angle (max): 26 degrees\u003c\/li\u003e\n\u003cli\u003eFoot-down tilt: 0 to 12 degrees\u003c\/li\u003e\n\u003cli\u003eProduct weight: 200.6 lb (91 kg) on transport stands\u003c\/li\u003e\n\u003cli\u003eSection weights: Backrest 50.7 lb (23 kg), leg section 44.1 lb (20 kg), bed ends 46.3 lb (21 kg) each\u003c\/li\u003e\n\u003cli\u003ePower supply: 120 V, 60 Hz, 1.7 A\u003c\/li\u003e\n\u003cli\u003eDuty cycle: 10% - 2 minutes of continuous use followed by 18 minutes not in use\u003c\/li\u003e\n\u003cli\u003eBattery backup: None as standard - the bed stays in its last position during a power failure\u003c\/li\u003e\n\u003cli\u003eLiquid ingress protection: IPX4, splash resistant\u003c\/li\u003e\n\u003cli\u003eNoise level: 66.9 dB(A) max\u003c\/li\u003e\n\u003cli\u003eElectrical class: Class II, Type BF applied part\u003c\/li\u003e\n\u003cli\u003eOperating environment: Indoor use only, on a flat level floor, 41 to 104 degrees F (5 to 40 degrees C)\u003c\/li\u003e\n\u003cli\u003eService life: 10 years with specified servicing\u003c\/li\u003e\n\u003cli\u003eWarranty: 1 year parts only when purchased from an authorized dealer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSizing\u003c\/h4\u003e\n\u003cp\u003eMeasure the floor space where the bed will stand, allowing clearance from walls and furniture for caregiver access and tilt, and check that your mattress fits the platform dimensions below. Mattresses must sit inside the side and foot-end mattress retainers.\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.5593%;\"\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.1479%;\"\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.5593%;\"\u003eOverall length\u003c\/td\u003e\n\u003ctd style=\"width: 53.1479%;\"\u003e87.8 in (223 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.5593%;\"\u003eOverall width\u003c\/td\u003e\n\u003ctd style=\"width: 53.1479%;\"\u003e39.96 in (101.5 cm) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.5593%;\"\u003eMattress platform length\u003c\/td\u003e\n\u003ctd style=\"width: 53.1479%;\"\u003e79.1 in (201 cm) extends to 85.6 in (217.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.5593%; height: 19.5938px;\"\u003eMattress Platform Size\u003c\/td\u003e\n\u003ctd style=\"width: 53.1479%; height: 19.5938px;\"\u003e80 x 35.6 in (201 x 90 cm); extends to 85.6 in (219 cm) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.5593%;\"\u003eMattress platform height\u003c\/td\u003e\n\u003ctd style=\"width: 53.1479%;\"\u003e11.6 to 28.2 in (29.5 to 71.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.5593%;\"\u003eUnder-bed clearance to frame, bed lowered\u003c\/td\u003e\n\u003ctd style=\"width: 53.1479%;\"\u003e9.7 in (24.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.5593%;\"\u003eUnder-bed clearance to actuator, bed lowered\u003c\/td\u003e\n\u003ctd style=\"width: 53.1479%;\"\u003e3.9 in (10 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eIntended Use\u003c\/h4\u003e\n\u003cp\u003eThe intended use of the bed is to support the weight of the patient whilst sleeping or resting and to assist the end user to gain and\/or maintain a suitable position. Beds are not intended for patient\/resident transport. Wheels are provided only to allow movement within the patient\/resident room for cleaning or patient\/resident access.\u003c\/p\u003e\n\u003cp\u003eThe bed is intended for use in a domestic area where the bed is used to alleviate or compensate for an injury, disability or disease, or a long term care area where medical supervision is required and monitoring is provided if necessary (e.g. nursing homes, rehabilitation facilities, geriatric facilities).\u003c\/p\u003e\n\u003ch4\u003eIndications\u003c\/h4\u003e\n\u003cp\u003eTo assist in the care and\/or comfort of the patient or care provider when the bed is used in the environments specified above.\u003c\/p\u003e\n\u003ch4\u003eContraindications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCervical or skeletal traction\u003c\/li\u003e\n\u003cli\u003eUnstable spinal fractures - if bed functions remain unlocked\u003c\/li\u003e\n\u003cli\u003eGeneral skeletal fractures - if relevant bed functions remain unlocked\u003c\/li\u003e\n\u003cli\u003ePatients who lack capacity\u003c\/li\u003e\n\u003cli\u003eConfused, agitated or restless\u003c\/li\u003e\n\u003cli\u003eExceeds maximum patient weight of bed\u003c\/li\u003e\n\u003cli\u003eLess than 57.5 in (146 cm) in length\u003c\/li\u003e\n\u003cli\u003eLess than 88.2 lb (40 kg) in weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eElectric beds should not be operated by persons who do not have the cognitive skills to understand the information in the owner's manual or cannot understand and perform the proper operation of the bed. This bed should not be used or operated by children.\u003c\/p\u003e\n\u003ch4\u003eHow It Works\u003c\/h4\u003e\n\u003cp\u003eThe handset drives electric linear actuators through a central control box. Bed-end actuators raise and lower the mattress platform and create the foot-down tilt, while separate actuators move the backrest and leg section. Holding a button operates the function; releasing it stops all movement. A key inserted into the handset locks or unlocks each function individually, and a yellow indicator shows when a function is locked.\u003c\/p\u003e\n\u003ch4\u003eSafety Information\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e exceed the safe working load. The safe working load is the combined total of the occupant, mattress, accessories and any mass they support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e let visitors sit on the side of the bed. The stated loads are for one occupant only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e use the bed if any hand wheel, clevis pin, R clip or locking collar is loose, missing or unlocked. Risk of bed collapse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e extend the bed while side rails are fitted. Remove side rails first.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e use a dynamic mattress with the bed in its extended state. A hazardous gap is created.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e use the bed to transport an occupant. The castors are for moving the bed within a room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e use electrically operated beds near flammable gases or in oxygen-rich environments. Keep the bed away from heat sources and naked flames.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not\u003c\/strong\u003e use accessories that are not approved for this bed.\u003c\/li\u003e\n\u003cli\u003eCarry out a patient risk assessment before use, covering entrapment, falls, small adults and children, patients who lack capacity, unauthorized access and use of accessories.\u003c\/li\u003e\n\u003cli\u003eLock out any function if there is doubt about the occupant's ability to operate the bed safely, and store the key out of reach to avoid a choking hazard.\u003c\/li\u003e\n\u003cli\u003eBefore lowering the bed, make sure no one is close to the underside of the frame. Keep limbs, bedding, cables and tubing clear of moving parts.\u003c\/li\u003e\n\u003cli\u003ePosition the handset cable and bed cables to minimize the risk of entanglement or strangulation.\u003c\/li\u003e\n\u003cli\u003eKeep portable RF communications equipment at least 12 in (30 cm) from any part of the bed.\u003c\/li\u003e\n\u003cli\u003eDrive recommends leaving the bed in its lowest position when the occupant is unattended.\u003c\/li\u003e\n\u003cli\u003eAssembly and servicing should be carried out by qualified personnel. Read the owner's manual before putting the bed into service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCare Instructions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the bed from the mains before cleaning and check all cable plugs are fully inserted to maintain the IP rating.\u003c\/li\u003e\n\u003cli\u003eWipe down with a clean cloth moistened with mild detergent in warm water at 104 degrees F (40 degrees C), rinse with cold clean water and allow to dry fully before use.\u003c\/li\u003e\n\u003cli\u003eFor decontamination, wipe with a 0.1% chlorine solution (1,000 ppm) in cold water, then rinse and dry. Use a 1% chlorine solution (10,000 ppm) for blood or bodily fluids.\u003c\/li\u003e\n\u003cli\u003eDry steam cleaning is permitted. Reduce steam pressure near electrical and wooden components. \u003cstrong\u003eDo not\u003c\/strong\u003e use neat bleach or high-pressure hoses.\u003c\/li\u003e\n\u003cli\u003eAvoid direct sunlight and damp environments.\u003c\/li\u003e\n\u003cli\u003eThe bed must be serviced at least once a year by authorized personnel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eResources\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2808\/7360\/files\/Solite_bed_manual.pdf?v=1785341337\" rel=\"noopener\" target=\"_blank\"\u003eSolite Pro Low Homecare Bed Owner's Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConsult a healthcare professional to determine whether this bed is appropriate for the occupant's needs, and carry out a risk assessment before use.\u003c\/p\u003e\n\u003ch4\u003ePackage Includes\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 x Covered bed ends with bed-end actuators and braked castors\u003c\/li\u003e\n\u003cli\u003e1 x Backrest section with control box and backrest actuator\u003c\/li\u003e\n\u003cli\u003e1 x Leg section with leg rest actuator\u003c\/li\u003e\n\u003cli\u003e2 x Transport stands\u003c\/li\u003e\n\u003cli\u003e1 x Handset with lockout key\u003c\/li\u003e\n\u003cli\u003e1 x Control box clip\u003c\/li\u003e\n\u003cli\u003e2 x Accessory sockets\u003c\/li\u003e\n\u003cli\u003e2 x Re-usable cable ties\u003c\/li\u003e\n\u003cli\u003e1 x Owner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDelivered in four boxes. Mattress, side rails and grab handles are not included.\u003c\/p\u003e","brand":"Drive Medical","offers":[{"title":"Default Title","offer_id":41265399890033,"sku":"DMC15006LP","price":2151.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2808\/7360\/files\/unnamed_7004b0bc-2e49-4028-911e-d2a22d4976ce.gif?v=1791580967","url":"https:\/\/healthcaresolutions.ca\/products\/drive-solite-pro-low-homecare-bed-frame-only","provider":"Healthcare Solutions","version":"1.0","type":"link"}