Medline FitGuard Touch Nitrile Exam Gloves, Powder-Free, Chemo-Tested
- Free shipping over $99
- Returns vary by item
- Print product sheet (opens in a new tab)
Description
Description
Not made with natural rubber latex. Powder-free. Non-sterile. Single use only. Contains accelerators. Not for use with Carmustine or Thiotepa.
Medline FitGuard Touch Nitrile Exam Gloves are powder-free, non-sterile examination gloves in a cobalt dark blue nitrile, with textured fingertips for grip and tactile sensitivity. They meet ASTM D6319 for nitrile examination gloves and have been tested for use with chemotherapy drugs per ASTM D6978, making them suited to healthcare and pharmacy settings for everyday examinations and hazardous drug handling. Sold by the box in sizes small to extra large.
Features
- Nitrile exam gloves, not made with natural rubber latex
- Powder-free
- Textured fingertips designed for grip while maintaining tactile sensitivity
- Meets ASTM D6319 for nitrile examination gloves
- Tested for use with chemotherapy drugs per ASTM D6978
- Beaded cuffs designed to help prevent rolling
- Bilingual English and French packaging
- Made in a WRAP-certified facility
Specifications
- Manufacturer: Medline Industries, LP
- Product line: FitGuard Touch
- Product type: Powder-free nitrile exam gloves
- Material: Nitrile
- Colour: Cobalt dark blue
- Texture: Textured fingertips
- Latex: Not made with natural rubber latex
- Accelerators: Yes
- Powder: Powder-free
- Sterility: Non-sterile
- Use: Single use only
- Standards: ASTM D6319, ASTM D6978 (chemotherapy drug permeation)
- Country of manufacture: China
Sizing
Measure around the widest part of your palm, excluding the thumb, and compare the measurement with Medline's FitGuard size chart. Gloves per box varies by size.
| Size | Medline REF | Gloves per box |
| Small | FG3001 | 300 |
| Medium | FG3002 | 300 |
| Large | FG3003 | 300 |
| Extra Large | FG3004 | 250 |
Chemotherapy Drug Permeation Testing
Tested for use with chemotherapy drugs per ASTM D6978. Gloves used for protection against chemotherapy drug exposure must be selected specifically for the type of chemotherapy agent used. Users are recommended to review the Safety Data Sheets for the chemotherapy drugs being used to determine the required level of protection.
| Drug | Concentration tested | Breakthrough detection time |
| Cyclophosphamide | 20.0 mg/ml (20,000 ppm) | No breakthrough up to 240 minutes |
| Doxorubicin | 2.0 mg/ml (2,000 ppm) | No breakthrough up to 240 minutes |
| Etoposide | 20.0 mg/ml (20,000 ppm) | No breakthrough up to 240 minutes |
| Fluorouracil | 50.0 mg/ml (50,000 ppm) | No breakthrough up to 240 minutes |
| Paclitaxel | 6.0 mg/ml (6,000 ppm) | No breakthrough up to 240 minutes |
| Cisplatin | 1.0 mg/ml (1,000 ppm) | No breakthrough up to 240 minutes |
| Dacarbazine | 10.0 mg/ml (10,000 ppm) | No breakthrough up to 240 minutes |
| Methotrexate | 25 mg/ml (25,000 ppm) | No breakthrough up to 240 minutes |
| Carmustine | 3.3 mg/ml (3,300 ppm) | Not for use with Carmustine |
| Thiotepa | 10.0 mg/ml (10,000 ppm) | Not for use with Thiotepa |
Safety Information
- Do not use with Carmustine or Thiotepa.
- Single use only. Do not reuse.
- Contains accelerators, which may cause skin reactions in people with accelerator sensitivity.
Storage and Disposal
Protect from freezing and avoid excessive heat. Keep dry. Shield from direct sunlight, fluorescent lighting, x-rays, moisture and ozone. Dispose of in accordance with local regulations.
Follow your workplace hazardous drug handling policy when selecting gloves for chemotherapy drug use.
Package Includes
- 1 x Box of Medline FitGuard Touch Nitrile Exam Gloves in your selected size
Shipping & Returns
Shipping & Returns
Shipping: Free shipping in Canada on orders over $99. Heavy and oversized items ship at a flat rate, confirmed with you by phone before delivery. Shipping details
Returns: Most new, unused items can be returned within 30 days. Health, hygiene and personal-care items, clearance and online-only items are final sale. See what can be returned